HP SMART ARRAY 5I CONTROLLER DRIVER DOWNLOAD

Power off the server. If the rebuild does not start, run ACU to initiate therebuild. Prior to its takeover the company was headquartered in a facility in northwest unincorporated Harris County, Texas, that now continues as HP’s largest United States facility. The low profile, half height card has 8 ports and utilizes DDR memory. Breaking a mirror and rebuilding the array using the manual method Shut down the server if this occurs. If you configure multiple arrays on asingle controller, all arrays must be broken and restoredtogether.

Uploader: Sham
Date Added: 26 August 2004
File Size: 29.27 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 64998
Price: Free* [*Free Regsitration Required]

Advertising seems to be blocked by your browser.

Veritas does not guarantee the accuracy regarding the completeness of the translation. The ads help us provide this software and web site msart you for free. Breaking a mirror and rebuilding the array using the manual method Don’t see a manual you are looking for? You may also refer to the English Version of this knowledge base article for up-to-date information. The controller is embedded on the system boards of the following servers: The array rebuild should start automatically.

  KINGSTON WPD DRIVER DOWNLOAD

Compaq Smart Array 5i Controller (QuickSpecs/cpdf)

Or point us to the URL where the manual is located. Splitting a mirrored array using the Array Configuration Utility Once you have expanded the array, you can either add new logical drives or use the LogicalDrive Extension function to grow the size of the existing logical drives.

Because of the added complexity for multiple arrays,we discourage this method of creating a backup of the logicaldriver. Compaq Smart Array 5i-Controller. Only stand-alone tape drives are supported on this controller.

Support policy for Host-Bus-Adapters that feature RAID

Reverting to a previous copy of a mirrored set using the ma nual method You can also use amanual method with any Smart Array controller. It is possible that updates have been made to the original version after this document was translated and published. Tell us what’s missing. Press F2 to fail the missing drive and continue with one drive in recovery mode. Power off the server. Page 6 Reverting to a previous copy of a mirrored smarrt using themanual methodThis method works only if you used coontroller manual method to break the mirrored set.

Boot-up message indicating the controller found no logical drives. Was this content helpful?

  CANON I550X XP DRIVER

Get the perfect match for your driver More than 5 million happy users. Industry Computer hardwareComputer software.

This adapter supports both 3Gb SAS and 1. Please note that this document is a translation from English, and may have been machine-translated.

If the rebuild does not start, run ACU to initiate therebuild. Boot-up message indicating that the logical drive is still available but missing physical drivesNOTEIf the logical drive fails and the server will not boot, youprobably removed two drives that were mirrored to one another.

Your browser security needs to be updated

Insert the drive you want to rebuild into the open drive bay. Visit Our Social Dashboard. Only download this driver.

Shut down the server if this occurs. Pfeiffer served through the s. Reinstall all drives andreboot. Please provide additional feedback optional: